Tweco 6000 CE Merlin User Manual
Page 25

Manual 0-2601
3-7
INSTALLATION PROCEDURES
A. Using Shop Air
An inline pneumatic dryer/evaporator type air filter, capable of
filtering particulates to at least 5 microns with a dew point of
35°F (1.7°C), is required when using air from a compressor. This
type filter will insure that moisture, oil, dirt, chips, rust particles,
and other contminants from the supply hose do not enter the
torch. For highly automated applications, a refrigerated drier
plus a particulate filter may be used to chill the air to remove all
moisture.
CAUTION
Excessive oil or moisture in compressed air will
reduce torch parts life and cutting performance and
may cause torch failure.
The optional Two Stage Air Line Filter is shipped with
the following components:
NOTE
The Two Stage Air Line Filter Assembly is to be
used when using shop air as the Plasma Gas.
• Installation Instructions - 1 each
• 10-32 Nylon Lock Nuts - 2 each
• Filter Mounting Bracket - 1 each
• Air Line Filter Assembly - 1 each
• 1/4 NPT Street Elbow - 1 each
• Thread Sealer - 1 each
• Filter To Plasma Gas Hose Assembly - 1 each (see NOTE)
• Filter to Gas Option Hose Assembly - 1 each (see NOTE)
NOTE
Only one of these will be used depending on con-
figuration of Power Supply.
Install the Two Stage Air Filter Kit as follows:
NOTE
Use these instructions only for Power Supplies that
DO NOT
have the Gas Control Option installed.
1. Remove the air supply input hose from the Plasma
Gas (Air) Input Fitting at the rear of the power sup-
ply, if already installed.
2. Locate the two mounting studs on the rear of the unit and
secure the Air Filter Mounting Bracket to the panel using
the two 10-32 Nylon Locking Nuts provided.
Air Filter
Mounting Bracket
Mounting
Nuts
Mounting
Studs
A-01336
Figure 3-8 Air Filter Mounting Bracket Installation
3. Place thread sealer on the threads of the 1/4 NPT Street
Elbow (see NOTE).
NOTE
Do Not use teflon tape as a thread sealer as small
particles of the tape may break off and cause the
small gas passage to be blocked in the torch.
4. Install the supplied 1/4 NPT Street Elbow into the
input port (IN) of the Air Line Filter Assembly.