INSTALLATION PROCEDURES

3-16

Manual 0-2601

Cable From

Gas Select Option

GAS CONTROL

Connector (J63)

A-01508

OUTPUT

TO

CONTROL
MODULE

AIR

PLASMA

INPUT

N

2

PLASMA

INPUT

O

2

PLASMA

INPUT

PLASMA GAS

Ar/H

2

PLASMA

INPUT

Figure 3-25 Optional Gas Control Interface Connection

3.13 Master/Slave Parallel Cable

Connection

The interface between the Master and Slave Power Sup-
ply is made through the Parallel Cable. Connect one end
of the cable to the rear of the Master Power Supply at J54.
The other end connects to the rear of the Slave Power
Supply at J15.

3.14 Lifting Options

WARNING

Do not lift a power supply equipped with a cylin-
der rack running gear.

The recommended method for lifting the power supply
is to use a forklift as follows:

1. Approach from the front or rear of the unit.

2. Place the forks between the rear wheels or the front

casters.

3. Center the forks under the unit and carefully check for

proper balance before lifting.

Approach From Front Or Rear

Do Not Lift From Sides

A-01499

Figure 3-26 Lifting the Power Supply

3.15 Pilot Resistor Adjustment

This Sub-Section applies only to the following Master and Slave
Power Supplies:

• Merlin 6000 Master Power Supplies with the revision let-

ter 'C' or later on the data tag

• Slave Power Supplies with the revision letter 'E' or later

on the data tag

• Slave Power Supplies that have been retrofitted with Pi-

lot Resistors

Master and Slave Power Supplies, as noted above, contain
adjustable pilot resistor circuits. For output current below 250A,
only the pilot circuit in the Master Power Supply is activated.
For output current above 250A the Master and Slave Power
Supply pilot circuits are activated.