INSTALLATION PROCEDURES

3-10

Manual 0-2601

D. Plasma and Secondary Gases With

Optional Gas Control

The required plasma and secondary gases are connected
to the rear of the Power Supply. The secondary selection
switch on the front panel of the Power Supply must al-
ways be set to GAS for all secondary gases when the Gas
Control Option is installed. The type of gas to be used
will be selected at the Gas Control Option front panel.

NOTE

If compressor shop air is to be used as the plasma
gas the line must be filtered.

If using shop air as one of the plasma gases then install
the optional Two Stage Air Line Filter as follows:

NOTE

Use these instructions only for Power Supplies
that HAVE the Gas Control Option installed.

1. Remove the air supply input hose from the Plasma Gas (Air)

Input Fitting at the rear of the power supply, if already in-
stalled.

2. Locate the two mounting studs on the rear of the unit and

secure the Air Filter Mounting Bracket to the panel using
the two 10-32 Nylon Locking Nuts provided.

Air Filter

Mounting Bracket

Mounting

Nuts

Mounting

Studs

A-01336

Figure 3-13 Air Filter Mounting Bracket Installation

3. Place thread sealer on the threads of the 1/4 NPT Street

Elbow (see NOTE).

NOTE

Do Not use teflon tape as a thread sealer as small
particles of the tape may break off and cause the
small gas passage to be blocked in the torch.

4. Install the supplied 1/4 NPT Street Elbow into the input port

(IN) of the Air Line Filter Assembly.

5. Slide the Air Line Filter Assembly into the mounting bracket.

The Filter Assembly will snap into place.

A-01339

1/4 NPT

Elbow

Air Filter

Assembly

Air Filter

Mounting

Bracket

OUTPUT

TO

CONTROL

CONTROL
MODULE

AIR

PLASMA

PLASMA
INPUT

N2

PLASMA

PLASMA
INPUT

O2

PLASMA

PLASMA
INPUT

PLASMA GAS

PLASMA GAS

Ar/H

Ar/H

2

PLASMA

PLASMA
INPUT

Hose

Assembly

Filter to

Plasma

Gas Input

Gas Control

Plasma Gas

Input Fitting

Figure 3-14 Supply Hose Connections With Gas Control

Option

6. Place thread sealer on the threads of the connectors at both

ends of the Filter to Plasma Input Gas Hose Assembly (see
NOTE).

NOTE

Do Not use teflon tape as a thread sealer as small
particles of the tape may break off and cause the
small gas passage to be blocked in the torch.

7.

Connect the Filter to Plasma Input Gas Hose Assem-
bly to the output port (OUT) of the Air Line Filter
Assembly and to the Air Plasma Input Fitting on the
Gas Control Manifold.

8. Place thread sealer on the threads of the Street Elbow

on a Y-Hose Assembly (see NOTES).

NOTES

Do Not use teflon tape as a thread sealer as small
particles of the tape may break off and cause the
small gas passage to be blocked in the torch.

The Y-Hose Assembly is customer supplied and is
shown to illustrate one method of connecting the
customer's air supply.

9. Connect the air supply hose from a Y-Hose Assembly

to the street elbow on the Air Line Filter input port
(IN). The Y-Hose Assembly should have already been
installed, if shop air was being used as the plasma