Timer operation, Only available for hot tub and floor operation, Remote enable – tekmar 161 Setpoint Control User Manuals User Manual
Page 9

9 of 12
© 2007
U 161 - 08/07
Timer Operation
The timer operation feature is only available when heating setpoints, hot tubs, or
radiant floors. It is not available when heating a domestic hot water tank.
The setpoint control can be set up to normally remain at the unoccupied temperature
setting. The setpoint control can be activated to temporarily operate at the occupied
temperature for a preset amount of time. This is similar to a windup timer.
To activate the occupied time on the setpoint control, press the Up or Down buttons
while in the View menu. The occupied time can also be activated through a remote
enable by pressing the button on a User Switch or through a tN4 Gateway if these
devices are installed.
When using the Up or Down buttons to activate the occupied time, the amount of
time for the occupied time can be set.
To cancel the occupied time, press and hold the Down arrow button while in the
View Menu until the time displays “OFF”.
The occupied time can also be canceled by pressing the button on a User Switch
or it can be canceled through the tN4 Gateway if these devices are installed.
Pressing the UP button while in the VIEW menu
starts operation of the Hot Tub for the time set.
To Stop operation press the DOWN button until
the time shows OFF.
Button Enable
Note:
Only available for Hot Tub and Floor operation.
User
Button
1
User
Button
2
User
Button
3
UnOcc
Occ
Press Button
User Switch
Setpoint
Control
Setpoint
Control
Remote Enable
Note: