Table a-5, Immunity tests – Cisco XR 12404 User Manual
Page 168
Appendix A Technical Specifications
Compliance Information
A-6
Cisco XR 12404 Router Installation Guide
OL-13830-02
ETSI
EN 300386-2/EN55022
B
(Noncentral office)
1. Up to 40 GHz
Table A-5
Immunity Tests
Test Type or Specification
Applies to
Class/Level/Criteria
Electrostatic Discharge
EN61000-4-2:1995
System/enclosure
Level 4/8KV contact, 15KV air/B
Radiated Immunity
IEC61000-4-3:1995
ENV50140:1993
System/enclosure
Level 3/10V/m/A
1KHz 80% AM
(80MHz - 1 GHz)
Fast Transients
EN61000-4-4:1995
AC power lines
DC lines
Signal lines
Level 4/4KV 2.5 kHz Rep Freq/B
Level 4/4KV 2.5 kHz Rep Freq/B
Level 4/1KV 5kHz Rep Freq/A
Level 4/2 KV 5kHz Rep Freq/B
Surge Immunity
EN61000-4-5:1995
AC power line (live-neutral)
2 ohms
AC power line (live-earth)
12 ohms
DC power line (live-earth)
DC Power line (return-earth)
Signal lines 2 ohms
Class 4/2KV/B
Class 4/4KV/B
Class 4/500V/B
Class 4/500V/B
Indoor: 500V
Outdoor: 4KV/R
Table A-4
Electromagnetic Emissions Requirements (continued)
Country
Standard Requirements
Class: Up to 1 GHz