Figure 3. hookup to a four-wire safety mat, Sm-ga-5a, Sm-ha-5a – Banner Safety Mat Monitoring Modules User Manual
Page 10

*
*
12-24V dc
or
115V ac or 230V ac
(depending on model)
Reset
Switch
Jumper for Auto Reset
MSC1 MSC3
MSC2 MSC4
L2
B2
MSC1
MSC2
Machine
Master Stop
Control
Elements
*Arc suppressors
(see WARNING)
Non-safety
Auxiliary
Monitor Contact
12-24V dc
System OK
Outputs
Energized
Non-safety
Monitor
Outputs
100 mA
max.
each Output
K1
A
6A max.
K2
A
K1
B
6A max.
K2
B
K1
C
6A max.
K2
C
K1
D
6A max.
K2
D
*
*
MSC3
MSC4
SM-GA-5A
for 12-24/115V
SM-HA-5A
for 12-24/230V
B1
S11
S12
S22
S21
S34
S33
S32
S35
13
14
23
24
33
34
43
44
51
52
Y31
Y32
Y35
Y30
A2
S32
S31
A1
L1
Machine
Control
Circuits
dc common
+V
dc common
+V
MSC
Monitor
Contacts
or Jumper
Mat
5A max.
K1E
K2E
S11
S12
S22
S21
Mat #n
Mat #1
Series Connection of Multiple Safety Mats
The number of mats is limited by the total
series resistance per input channel. See
section, “Safety Mat Device Checkout” and
warning, ”Safety Mat Resistance Values.”
Figure 3. Hookup to a Four-Wire Safety Mat
Auxiliary Monitor Contact/Solid-State Monitor Outputs Connection
The action of the auxiliary monitor contact, terminals 51-52, inversely "follows" the action of the safety outputs. Two additional solid-state
monitor outputs (at terminals Y32 and Y35) each are capable of switching up to 100 mA at 12- 24V dc. The output at terminal Y32 follows
SM-xA-5A Safety Mat Monitoring Modules
10
www.bannerengineering.com - tel: 763-544-3164
P/N 122364_Web
rev. C