beautypg.com

Figure 3. hookup to a four-wire safety mat, Sm-ga-5a, Sm-ha-5a – Banner Safety Mat Monitoring Modules User Manual

Page 10

background image

*

*

12-24V dc

or

115V ac or 230V ac

(depending on model)

Reset

Switch

Jumper for Auto Reset

MSC1 MSC3

MSC2 MSC4

L2

B2

MSC1

MSC2

Machine
Master Stop
Control
Elements

*Arc suppressors
(see WARNING)

Non-safety

Auxiliary

Monitor Contact

12-24V dc

System OK

Outputs

Energized

Non-safety

Monitor

Outputs

100 mA

max.

each Output

K1

A

6A max.

K2

A

K1

B

6A max.

K2

B

K1

C

6A max.

K2

C

K1

D

6A max.

K2

D

*

*

MSC3

MSC4

SM-GA-5A

for 12-24/115V

SM-HA-5A

for 12-24/230V

B1

S11

S12

S22

S21

S34

S33

S32

S35

13

14

23

24

33

34

43

44

51

52

Y31

Y32

Y35

Y30

A2

S32

S31

A1

L1

Machine

Control

Circuits

dc common

+V

dc common

+V

MSC
Monitor
Contacts
or Jumper

Mat

5A max.

K1E

K2E

S11

S12

S22

S21

Mat #n

Mat #1

Series Connection of Multiple Safety Mats
The number of mats is limited by the total
series resistance per input channel. See
section, “Safety Mat Device Checkout” and
warning, ”Safety Mat Resistance Values.”

Figure 3. Hookup to a Four-Wire Safety Mat

Auxiliary Monitor Contact/Solid-State Monitor Outputs Connection

The action of the auxiliary monitor contact, terminals 51-52, inversely "follows" the action of the safety outputs. Two additional solid-state
monitor outputs (at terminals Y32 and Y35) each are capable of switching up to 100 mA at 12- 24V dc. The output at terminal Y32 follows