Output Rating
STBVP6 models (solid-state outputs):
Max. load: 150 mA
On-state max. output voltage (no load): +V(supply) − 1.5 V
Off-state leakage current: < 1 μA
STBVR81 models (electromechanical relays):
Max. switching voltage: 125 V dc/150 V ac
Max. switching current: 1 A @ 24 V dc; 0.4 A @ 125 V ac (resistive loads)
Max. resistive power: 24 W dc/50 VA ac
Mechanical life of relays: 10^9 cycles
Electrical life of relays: 1.5 x 10^5 cycles at 1 amp, 24 V resistive
Output Protection Circuitry
All models protected against false pulse on power-up. Models with solid-state outputs have overload and short-
circuit protection.
Output Response Time
20 milliseconds ON/OFF
Indicators
2 green LED indicators:
Power: ON – power applied
Output/fault: ON – button is activated; OFF – button is deactivated; Flashing – internal fault or blocked button
on power-up detected
Connections
PVC-jacketed 2 m (6.5') cables or QD fitting, depending on model; integral 9 m (30') cables are also available.
Accessory QD cables required for QD models.
STBVP6 models: 4-wire (4-pin Mini-style or Euro-style QD)
STBVR81 models: 5-wire (5-pin Mini-style or Euro-style QD)
Environmental Rating
Meets NEMA standards 1, 3, 4, 4X, 12 and 13; IEC IP66
Construction
Totally encapsulated, non-metallic enclosure. Black polyetherimide upper housing; fiber-reinforced PBT polyester
base. Electronics fully epoxy-encapsulated. Supplied with polypropylene (TP) field cover.
Ambient Light Immunity
Up to 100,000 lux
Applicable Agency Standards
(Used with an AT-FM-10K module or an SC22-3 Safety Controller) Analysis of measures for fault avoidance and
fault control according to SIL3 (IEC 61508 and IEC 62061) and Category 4 (EN ISO 13849-1) passes EMI/RFI test
levels as speCified in IEC61496 and IEC62061..
Operating Conditions
0 to 50 °C (32 to 122 °F)
90% @ 55 ºC max. relative humidity (non-condensing)
Application Notes
The polyetherimide upper housing will become brittle with prolonged exposure to outdoor sunlight. Window glass
effectively filters longer wavelength ultraviolet light and provides excellent protection from sunlight. Avoid contact
with strong alkalis, hydrocarbons and fuels. Clean periodically using mild soap solution and a soft cloth.
Two-Hand Control System Note
When the STBVP6 is used with Banner’s SC22-3 Safety Controller in a two-hand control system, the power supply
to the STBVP6 must be of the same voltage that is used to power the Safety Controller and they must have a
common supply ground.
Certifications
STB Self-Checking Optical Touch Buttons
8
www.bannerengineering.com - tel: 763-544-3164
P/N 64136 Rev. C