Solid-state, Bn bl, Bn bl yl wh bu wh bu – Banner DUO-TOUCH Run Bar with STB Buttons User Manual
Page 7: Relay, Repairs, Specifications
WARNING:
Safety Systems Used for Two-Hand-Control. In a two-hand-control/trip system that incorporates STB
Touch Buttons as the actuation devices and functions as a safeguard, the anti-tiedown and simultaneity
monitoring functions should not be performed by a nonsafety-related device (e.g., a PLC or PC). Per
OSHA 29CFR1910.211(d)(62), the “safety system must...operate together as a unit, such that a single
failure or single operating error will not cause injury to personnel due to point-of-operation hazards.”
Refer to the appropriate standard to determine the requirements of a two hand-control/trip system
when used for safeguarding.
Solid-State
10-30V dc
V+
V+
bn
bl
bn bl
yl
wh
bu
wh
bu
Micro-
Controller
1
Relay
20-30V ac/dc
V+
V+
Micro-
Controller
2
Micro-
Controller
1
Micro-
Controller
2
K
1
K
1
K
2
K
2
A
1
+
–
A
2
Figure 4. STB Touch Button block diagrams
Repairs
Contact Banner Engineering for troubleshooting of this device. Do not attempt any repairs to this Banner device; it
contains no field-replaceable components. If the device or a device component is determined to be defective by a
Banner Applications Engineer, they will advise you of Banner's RMA (Return Merchandise Authorization) procedure.
Important: If instructed to return the device, pack it with care. Damage that occurs in return shipping
is not covered by warranty.
Specifications
Supply Voltage and Current
STBVP6 models: 10 to 30 V dc @ 75 mA, typical
STBVR81 models: 20 to 30 V ac/dc or 20 to 30 V ac (peak-to-peak value), (50/60 Hz ±5%) @ 75 mA
Supply Protection Circuitry
Protected against reverse polarity and transient voltages
Output Configuration
STBVP6 models: Complementary PNP (sourcing) open-collector transistors
STBVR81 models: Complementary electromechanical relays
STB Self-Checking Optical Touch Buttons
P/N 64136 Rev. C
www.bannerengineering.com - tel: 763-544-3164
7