beautypg.com

Repairs, Specifications – Banner SI-QM100 Locking Style Switches User Manual

Page 6

background image

1. Check the wiring chamber for signs of contamination.
2. Check the contacts for signs of deterioration or damage.
3. Inspect the electrical wiring for continuity and damage.
4. Verify the wiring conforms to the instructions given in this datasheet.

A designated person is identified in writing by the employer as being appropriately trained to perform a specified checkout procedure. A
qualified person possesses a recognized degree or certificate or has extensive knowledge, training, and experience to be able to solve
problems relating to the safety switch installation (ANSI B30.2).

Repairs

Do not attempt any repairs to the Module. It contains no field-replaceable components. Return it to the factory for warranty repair
or replacement by contacting Banner Factory Application Engineering. They will attempt to troubleshoot the system from your description
of the problem. If they conclude a component is defective, they will issue a return merchandise authorization (RMA) number for your
paperwork and give you the proper shipping address.
Pack the Module carefully. Damage that occurs in return shipping is not covered by warranty.

CAUTION: Abuse of Module After Failure
If an internal fault has occurred and the Module will not reset, do not tap, strike, or otherwise attempt to
correct the fault by a physical impact to the housing.
An internal relay may have failed in such a man-
ner that its replacement is required.
If the Module is not immediately replaced or repaired, multiple simultaneous failures may accumu-
late such that the safety function can not be guaranteed.

Specifications

Contact Rating

4A @ 250V ac max.
2.5 kV max. transient tolerance
NEMA A300 P300

Contact Material

Silver-nickel alloy

Solenoid Power Consumption

5.2 W

Maximum Actuator Speed

1.5 m/second (5 ft/second)

Minimum Actuator Engagement Radius

In-line actuators: 400 mm (16 inches)
Flexible actuators: 150 mm (6 inches)

Actuator Extraction Force

1000 Newtons (220 lbf) when locked

Mechanical Life

1 million operations

Construction

Aluminum die-cast housing

Weight

0.81 kg (1.79 lb)

Environmental Rating

IEC IP67

Operating Conditions

Temperature: –30° to +60° C (–22° to +140° F)

European Rating

Utilization categories: AC15 and DC13 (IEC 60947-5-1)
Switches with 1 and 2 contact pairs: Ui = 250V ac; Ith =
10A

40-60 Hz

Ue

V

Ie/AC-15

A

Ie/AC-13

A

24

4

3

110

4

0.7

230

4

0.3

Short Circuit Protection

6 amp Slow Blow, 10 amp Fast Blow. Recommended
external fusing or overload protection.

Wire Connections

Screw terminals with pressure plates accept the follow-
ing wire sizes—
16 AWG (1.5 mm

2

) max. solid; 14 AWG (2.5 mm

2

)

max. stranded, 18 AWG (1 mm2) when using all 11 ter-
minals

Cable Entry

M20 x 1.5 threaded entrance. Adapter supplied to con-
vert M20 x 1.5 to ½" - 14 NPT threaded entrance.

Machine Safety Switches

6

www.bannerengineering.com - tel: 763-544-3164

P/N 049374 Rev. F

This manual is related to the following products: