41 and, Generic, Generic wiring — interface module – Banner EZ-SCREEN Safety Light Curtain Systems User Manual
Page 42: Channel edm, manual reset), Generic wiring — interface module (2-channel, Edm, manual reset)
Generic Wiring — Interface Module (2-Channel EDM, Manual Reset)
+24V dc
0V dc
S1
S2
Y4
Y2
14
24
34
S3
S4
Y3
Y1
13
23
33
K2
K1
Machine
Control
MPCE
2
MPCE
1
IM-T-9A**
Bn (Pin #1)
+24V dc
0V dc
OSSD 1
OSSD 2
MPCE Monitoring
Reset/
Test
n.c.
N.C.
n.c.
Ground
Gn/Ye (#7)
Bu (#6)
Bk (#5)
Wh (#4)
Vi (#8)
Or (#3)
Or/Bk (#2)
*
*
Receiver
8-pin male Euro-style
face view
*
NOTE:
• Pins 2 and 3 are not connected, or are connected in parallel to the same color wire from the emitter cord-
set and properly terminated.
• Installation of transient (arc) suppressors across the coils of MPCE1 and MPC2 is recommended.
• See
Single-Ended (Machine Interface) Cordsets
on page 57 for available cordset information
Other interfacing modules and solutions are available, see
on page 57.
WARNING: Use of Transient Suppressors
If transient suppressors are used, they MUST be installed across the coils of the machine control ele-
ments. NEVER install suppressors directly across the contacts of the IM-T-..A Module. It is possible for
suppressors to fail as a short circuit. If installed directly across the contacts of the IM-T-..A Module, a
short-circuit suppressor will create an unsafe condition
EZ-SCREEN® Type 2 Light Screen Instruction Manual
42
www.bannerengineering.com - tel: 763-544-3164
122452 rev. B