Generic wiring to fsds (manual reset), Ring). see, Ez-screen generic fsds wiring – Banner EZ-SCREEN Safety Light Curtain Systems User Manual
Page 41: Ossd outputs. refer to
Generic Wiring to FSDs (manual reset)
+24V dc
0V dc
Receiver
8-pin male Euro-style
face view
*
Bn (Pin #1)
Gn/Ye (#7)
Bu (#6)
Bk (#5)
Wh (#4)
Vi (#8)
Or (#3)
Or/Bk (#2)
+24V dc
Ground
0V dc
OSSD1
OSSD2
Reset/Test
Manual Test
or Reset
(Latch or Lockout)
Automatic
Test
FSD
Monitoring
Circuit
n.c.
n.c.
FSD
2
FSD
1
Single-Channel
Safety Stop
Circuit
Dual-Channel
Safety Stop
Circuit
NOTE: Do not exceed OSSD maximum load
capacitance specification.
*See
Single-Ended (Machine Interface) Cordsets
on page 57 for available cordsets
NOTE: Pins 2 and 3 are not connected, or are connected in parallel to the same color wire from the emitter
cordset and properly terminated.
EZ-SCREEN® Type 2 Light Screen Instruction Manual
122452 rev. B
www.bannerengineering.com - tel: 763-544-3164
41