WARNING: Synchronization
In situations where multiple systems are mounted closely together, or where a secondary emitter is in view
(within ±5°), within range of an adjacent receiver; a receiver may synchronize to the signal from the wrong
emitter, reducing the safety function of the light screen.
WARNING: Multiple Pairs of Sensors
Do not connect multiple pairs of sensors to one Interface Module (for example, IM-T-9A/-11A) or otherwise
parallel OSSD outputs.
Connection of multiple OSSD safety outputs to a single device can result in an increased risk of
harm, and is prohibited.
Mounting System Components
Overview of Emitter/Receiver Mounting Hardware
Mounting Hardware
The EZ-SCREEN standard end-cap mounting bracket hardware is
supplied with each emitter and receiver. Brackets are designed to
mount directly to MSA Series stands using the hardware with the
supplied stands.
EZ-SCREEN® Type 2 Light Screen Instruction Manual
122452 rev. B
www.bannerengineering.com - tel: 763-544-3164
23