Rockwell Automation RECOMM-CNET ControlNet Communications Module User Manual
Page 29

Configuring the ControlNet Module
4-9
14
DPI I/O Active
I/O that the module is actively transmitting. The
value of this parameter will usually be equal to the
value of parameter 13 - DPI I/O Config.
Default:
xxx0 0001
Bit Values:
0 = I/O disabled
1 = I/O enabled
Type:
Read Only
Bit Definitions
0 = Cmd/Ref
1 = Datalink A
2 = Datalink B
3 = Datalink C
4 = Datalink D
5 = Not Used
6 = Not Used
7 = Not Used
25
M-S Input
Configures the I/O Data to be transferred from the
network to the drive.
Default:
xxx0 0001
Bit Values:
0 = I/O disabled
1 = I/O enabled
Type:
Read/Write
Reset Required: Yes
Bit Definitions
0 = Cmd/Ref
1 = Datalink A
2 = Datalink B
3 = Datalink C
4 = Datalink D
5 = Not Used
6 = Not Used
7 = Not Used
26
M-S Output
Configures the I/O Data to be transferred from the
drive to the network.
Default:
xxx0 0001
Bit Values:
0 = I/O disabled
1 = I/O enabled
Type:
Read/Write
Reset Required: Yes
Bit Definitions
0 = Cmd/Ref
1 = Datalink A
2 = Datalink B
3 = Datalink C
4 = Datalink D
5 = Not Used
6 = Not Used
7 = Not Used
27
Ref Adjust
Percent scale factor for the Reference from the
Network.
Default: 100.00
Minimum: 0.00
Maximum: 200.00
Type: Read/Write
Reset Required: No
Table 4.4 – Module Configuration Status Parameters
No.
Name and Description
Details
Bit
Default
1
0
0
0
0
x x
x
0
1
2
3
4
5
7
6
Bit
Default
1
0
0
0
0
x x
x
0
1
2
3
4
5
7
6
Bit
Default
1
0
0
0
0
x x
x
0
1
2
3
4
5
7
6