Rockwell Automation RECOMM-CNET ControlNet Communications Module User Manual
Page 101

Troubleshooting the ControlNet Module and Network
8-7
17
Datalink B1 Out
The current value of Datalink B1 being received
from the host.
18
Datalink B2 Out
The current value of Datalink B2 being received
from the host.
19
Datalink C1 Out
The current value of Datalink C1 being received
from the host.
20
Datalink C2 Out
The current value of Datalink C2 being received
from the host.
21
Datalink D1 Out
The current value of Datalink D1 being received
from the host.
22
Datalink D2 Out
The current value of Datalink D2 being received
from the host.
23
DPI Rx Errors
The current value of the DPI Receive error
counter.
24
DPI Rx Err Max
The maximum value (since reset) of the DPI
Receive error counter.
25
DPI Tx Errors
The current value of the DPI Transmit error
counter.
26
DPI Tx Err Max
The maximum value (since reset) of the DPI
Transmit error counter.
27
Node Address SW
The current value set on the Node Address
Switches.
28
Boot Flash Count
The number of times the Boot flash segment has
been updated in the field.
29
App Flash Count
The number of tmes the Application flash
segment has been updated in the field.
30
M-S Input Size
The size of data transferred from the network to
the drive.
31
M-S Output Size
The size of data transferred from the drive to the
network.
Table 8.5 – Module Diagnostic Items (Continued)
No.
Event
Description