2 key descriptions – Rockwell Automation SP500 AC Drive Installation and Operation Manual User Manual
Page 66
7-2
SP500 AC Drive Installation and Operation Manual Version 3.1
7.2
Key Descriptions
The keypad’s six membrane keys are used to monitor, program, and control the drive.
Table 7.1 describes the keys.
Table 7.1 – Key Descriptions
Use the UP and DOWN arrow keys to:
•
Step through the drive parameters and error log when the drive is in program mode.
•
Increase or decrease a parameter’s numeric value or status in program mode.
•
Increase or decrease the internal speed reference when F-00 (Control Source Select) =
0 or 2.
Hold down these keys to increase the scroll speed.
Use the MODE/ENTER key to:
•
Advance through each monitor display item in monitor mode.
•
Select program mode when the drive is stopped.
•
Display a parameter value in program mode.
•
Save a parameter value in program mode.
The MODE/ENTER key provides these functions regardless of the control source selected
(local or remote).
Use the FORWARD/REVERSE key to select the direction of motor shaft rotation when the
control source is local (F-00 = 0).
Use the START key to apply power to the motor when the control source is local (F-00 = 0).
When this key is pressed, and there are no active faults, the drive will accelerate to the last
programmed frequency setpoint (speed).
Use the STOP/RESET key to:
•
Turn off the drive output to the motor if the drive is running.
•
Clear drive faults when the drive is in program mode.
•
Exit program mode.
When this key is pressed, the drive will ramp to rest at a user-defined rate (user option) or
coast to rest (default). This key stops the drive regardless of the selected control source
(remote or local).
Mode
Enter
Forward
Reverse
START
STOP
RESET