Rockwell Automation 2093-AMxx Kinetix 2000 Drive Systems Design Guide User Manual
Page 30
30
Rockwell Automation Publication GMC-RM006A-EN-P - September 2011
Kinetix 2000 Drive Systems
Performance Specifications with Roller Screw Electric Cylinders
Performance specification data and curves reflect nominal system performance of a typical system with actuator at 40 °C (104 °F) and drive at 50 °C (122 °F) ambient and rated line voltage. For additional
information on ambient and line conditions, refer to Motion Analyzer software, version 4.8 or later.
Electric Cylinder
Speed, max
mm/s (in/s)
System Continuous
Stall Current
Amps 0-pk
System Continuous Stall Force
N (lb)
System Peak
Stall Current
Amps 0-pk
System Peak
Stall Force
N (lb)
Rated Output
kW
Kinetix 6000
200V-class Drives
25 °C (77 °F)
40 °C (104 °F)
MPAI-A3076RM1
305 (12)
2.87
1557 (350)
1237 (278)
8.90
4862 (1093)
0.27
2093-AMP5
MPAI-A3076SM1
610 (24)
778 (175)
618 (139)
2431 (547)
MPAI-A3150RM3
279 (11)
5.61
3781 (850)
3003 (675)
14.14
7562 (1700)
0.39
2093-AM01
MPAI-A3300RM3
MPAI-A3450RM3
176 (6.9)
MPAI-A3150SM3
559 (22)
1891 (425)
1499 (337)
3781 (850)
MPAI-A3300SM3
MPAI-A3450SM3
353 (14)
MPAI-A4150RM3
279 (11)
10.89
7340 (1650)
5827 (1310)
27.44
14,679 (3300)
0.43
2093-AM02
MPAI-A4300RM3
MPAI-A4450RM3
196 (7.6)
MPAI-A4150SM3
559 (22)
3670 (825)
2914 (655)
7340 (1650)
MPAI-A4300SM3
MPAI-A4450SM3
393 (15)