Kinetix 2000 Drive Systems
Kinetix 2000 Drives with MP-Series Stainless Steel Motors
This section provides system combination information for the Kinetix 2000 (200V class) drives when matched with
MP-Series (200V class) stainless-steel motors. Included are motor power/brake and feedback cable catalog numbers, system
performance specifications, and the optimum torque/speed curves.
Bulletin MPS Motor Cable Combinations
For cable configuration illustrations and feature descriptions, by catalog number, refer to 2090-Series Motor/Actuator Cables Overview beginning on
.
Motor-end connector kits, and panel-mounted breakout components (drive end), are available for motor power/brake and feedback cables. Refer to Optional Drive Accessories on
.
Cable length xx is in meters. Refer to the Kinetix Motion Accessories Technical Data, publicat
, for standard cable lengths.
Bulletin MPS Motor Performance Specifications with Kinetix 2000 Drives
Kinetix 2000 Drives with MP-Series Stainless Steel Motor Curves
Motor Cat. No. (200V class)
Motor Power/Brake Cable
Motor Feedback Cable
(1)
(1) Use low-profile connector kit (catalog number 2090-K2CK-D15M) on the drive end. Refer to Required Drive Accessories on
.
MPS-A330P
2090-XXNPMF-16Sxx (standard, non-flex)
2090-CPxM4DF-16AFxx (continuous-flex)
2090-XXNFMF-Sxx (standard, non-flex)
2090-CFBM4DF-CDAFxx (continuous-flex)
Absolute High-resolution Feedback
Rotary Motor
Speed, max
rpm
System Continuous
Stall Current
A 0-pk
System Continuous
Stall Torque
N•m (lb•in)
System Peak
Stall Current
A 0-pk
System Peak
Stall Torque
N•m (lb•in)
Motor Rated
Output
kW
Kinetix 2000
200V-class Drives
MPS-A330P
5000
9.80
3.60 (32.0)
38.0
11.10 (98)
1.3
2093-AM02
Torque
(N•m)
Torque
(lb•in)
2093-AM02 and MPS-A330P
Speed (rpm)
0
2000
4000
3000
1000
5000
12.0
10.0
8.0
6.0
4.0
2.0
0
106
88.5
70.8
53.1
35.4
17.7
0
= Intermittent operating region (three-phase input)
= Continuous operating region
= Drive operation (single-phase input)