Rockwell Automation 2093-AMxx Kinetix 2000 Drive Systems Design Guide User Manual
Page 19
Rockwell Automation Publication GMC-RM006A-EN-P - September 2011
19
Kinetix 2000 Drive Systems
Bulletin TLY (brake) Motor Performance Specifications with Kinetix 2000 Drives
Kinetix 2000 Drives/TLY-A
xxxP-B (absolute high-resolution) Motor Curves
Rotary Motor
Speed, max
rpm
System Continuous
Stall Current
A 0-pk
System Continuous
Stall Torque
N•m (lb•in)
System Peak
Stall Current
A 0-pk
System Peak
Torque
N•m (lb•in)
Motor Rated
Output
kW
Kinetix 2000
200V-class Drives
TLY-A110x
6000
(1)
(1) Applies to TLY-AxxxT-H motors with incremental feedback. The TLY-AxxxP-B motors with absolute high-resolution encoders are rated at 5000 rpm.
0.50
0.086 (0.76)
1.50
0.20 (1.75)
0.037
2093-AMP1
TLY-A120x
0.93
0.163 (1.44)
2.50
0.36 (3.20)
0.077
2093-AMP1
TLY-A130x
1.67
0.293 (2.59)
4.90
0.76 (6.70)
0.13
2093-AMP2
TLY-A220x
3.15
0.757 (6.70)
7.90
1.48 (13.1)
0.24
2093-AMP5
TLY-A230x
4.95
1.16 (10.3)
15.5
3.05 (27.0)
0.32
2093-AM01
TLY-A2530P
5000
10.0
2.60 (23.0)
21.0
5.20 (46.0)
0.55
2093-AM02
TLY-A2540P
10.0
2.94 (26.0)
24.8
7.10 (63.0)
0.66
2093-AM02
TLY-A310M
4500
10.0
3.61 (31.9)
30.0
9.0 (79.6)
0.90
2093-AM02
Torque
(N•m)
Torque
(lb•in)
Speed (rpm)
2093-AMP1 and TLY-A110P-B
0
3000
5000
0.250
0.200
0.150
0.100
0.050
0
4000
1000
2000
2.21
1.77
1.33
0.88
0.44
0
Intermittent curve represents
three-phase and single-phase inputs.
Torque
(N•m)
Torque
(lb•in)
Speed (rpm)
2093-AMP1 and TLY-A110P-B (Brake)
0
3000
5000
0.250
0.200
0.150
0.100
0.050
0
4000
1000
2000
2.21
1.77
1.33
0.88
0.44
0
Intermittent curve represents
three-phase and single-phase inputs.
Torque
(N•m)
Torque
(lb•in)
Speed (rpm)
2093-AMP1 and TLY-A120P-B
0
3000
5000
0.400
0.350
0.300
0.250
0.200
0.150
0.100
0.050
0
4000
1000
2000
3.54
3.10
2.65
2.21
1.77
1.33
0.88
0.44
0
Intermittent curve represents
three-phase and single-phase inputs.
Torque
(N•m)
Torque
(lb•in)
Speed (rpm)
2093-AMP1 and TLY-A120P-B (Brake)
0
3000
5000
0.400
0.350
0.300
0.250
0.200
0.150
0.100
0.050
0
4000
1000
2000
3.54
3.10
2.65
2.21
1.77
1.33
0.88
0.44
0
Intermittent curve represents
three-phase and single-phase inputs.
= Intermittent operating region (three-phase input)
= Continuous operating region
= Drive operation (single-phase input)