Programming Reference

4-21

Selections 2 and 3 select the same signals as selections 0 and 1, but instead of
providing a 5 V (1/2 scale) offset to allow for a bipolar signal, no 5 V offset is used.
Instead, the signal is presented in a unipolar manner. The absolute value of the
selected signal is used to drive the analog output over its full range of 0 to 10VDC.
This provides greater resolution of the selected signal at the expense of indicating
polarity. Refer to figure 4.2.

Note that in V/Hz control, signals are updated every 500 ms. In Vector control, all
signals are updated every 5.0 ms.

P.012 Terminal Strip Analog Output Source

This parameter
selects the source of
the analog output
signal.

Parameter Range:

0 = Speed (bipolar)

1 = Torque (bipolar)

2 = Speed (unipolar)

3 = Current (unipolar) (V/Hz)

Torque (unipolar) (vector)

Default Setting:

0

Parameter Type:

Tunable

Refer also to parameters:

N/A

Figure 4.2 – Analog Output Selection and Scaling