Wire the Input Power Connector

You can use a 120V AC or 240V DC power source to connect input power to the
2097-V31PR2-LM drive via the IPD connector. In this quick start, we describe how to connect a
120V AC power source to the drive.

Complete these steps to wire the IPD connector.

1.

Verify the 120V AC power source is not powered.

2.

Remove the IPD connector plug
from the top of the drive.

3.

Remove approximately 7 mm
(0.28 in.) insulation from four
2.5 mm

2

(14 AWG)

copper wires.

4.

Insert the wires from the 120V
AC power source cable into the
IPD connector positions
according to the following table.

The L2/N connector is not used when connecting input power from a 120V AC
power source.

5.

Insert the connector plug into the location shown above.

Power Cable Wire Terminal

Black

L1

White

N

Green

PE

IMPORTANT

Do not connect power to the external power supply.

L2/N

L1

N

PE