S.m.a.r.t. start parameter setup, Identity – Rockwell Automation 20B PowerFlex 70 / 700 Parameters FRN 3.xx User Manual
Page 2
![background image](/manuals/580976/2/background.png)
Par
Parameter Name
Factory Default
Programmed Value
40
Motor Type
Induction
41
Motor NP Volts
Based on Drive Rating
42
Motor NP FLA
Based on Drive Rating
43
Motor NP Hertz
Based on Drive Cat. No.
44
Motor NP RPM
1750 RPM
45
Motor NP Power
Based on Drive Rating
46
Mtr NP Pwr Units
Based on Drive Rating
47
Motor OL Hertz
Motor NP Hz/3
48
Motor OL Factor
1.00
53
Torque Perf Mode
Sensrls Vect
61
Autotune
Calculate
62
IR Voltage Drop
Based on Drive Rating
63
Flux Current Ref
Based on Drive Rating
81
Minimum Speed
0.0 Hz
82
Maximum Speed
50.0 or 60.0 Hz
83
Overspeed Limit
10.0 Hz
90
Speed Ref A Sel
Analog In 2
91
Speed Ref A Hi
[Maximum Speed]
92
Speed Ref A Lo
0.0 Hz
140
Accel Time 1
10.0 Secs
142
Decel Time 1
10.0 Secs
201
Language
Not Selected
320
Anlg In Config
0
321
Anlg In Sqr Root
0
322
Analog In 1 Hi
10.0 Volt
323
Analog In 1 Lo
0.0 Volt
324
Analog In 1 Loss
Disabled
361
Digital In1 Sel
Stop - CF
362
Digital In2 Sel
Start
S.M.A.R.T. Start
Parameter Setup
Customer Name ____________________
Plant ____________________
Machine # ____________________
Process Number ____________________
Other Data ____________________
Date Programmed ____________________
SW Version ____________________
Drive Cat # ____________________
Drive Ser # ____________________
Identity