Rockwell Automation 57C332 AutoMax Power Supply Module and Racks User Manual
Page 15
2Ć7
(Nameplate Bracket Removed)
Figure 2.5 Ć 16ĆSlot Rack
Dedicated signal lines on the Multibus backplane require limitations
on slot placement for some types of DCS5000/AutoMax modules.
See figure 2.6.
Module Slot Position
Module
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
6ĆSlot Rack:
Common
Memory
D
Processor
D D D D D
DCSDC Drive
1
All Other
D D D D D D
10ĆSlot Rack:
Common
Memory
D
Processor
D D D D D
DCSDC Drive
2
D D D D
All Other
D D D D D D D D D D
16ĆSlot Rack:
Common
Memory
D
Processor
D D D D D
DCSDC Drive
2
D D D D
D
D
D
D
All Other
D D D D D D D D D D D
D
D
D
D
D
1
Cannot be used in a 6ĆSlot Rack.
2
Must be grouped together.
Figure 2.6Ć Rack Slot Limitations