Publication 2707-UM005AB-EN-P

Initial Setup and Mode Menu 3-9

To Enable or Disable Scaling:

1. From the Mode Menu, select item [4] Other.

The Other Menu appears:

2. Select item [2] Scal.

The scale enable screen displays:

3. Press [1] on the keypad to enable scaling and [0] to disable

scaling. The screen will display:

After the new parameter is saved, the MicroView will again
display:

4. Select item [5] Ex to exit to the Mode Menu.

Using Simulate Mode

The Simulate mode checks an application without having a controller
connected. All data that normally would be sent by the controller,
such as data for a display, is set to “0”. Any ASCII data is set to “?”.
Selecting the Simulate function from the Mode Menu will:

Halt communication between the MicroView and the controller.

Simulate communication with a controller.

Disabling the Simulate mode resumes normal operation.

1 Reset
2 Comm

3 Spec
4 Other

1 Master
2 Scal

3 Sim
4 Test

5 Ex

Current Setting

Scale
0 = Off

OFF (0)
1 = On

COPYING TO MEM
Please Wait . . .

1 Master
2 Scal

3 Sim
4 Test

5 Ex