Rockwell Automation 2090-xxx Fiber Optic Cable Installation and Handling Instructions User Manual
Page 11

Fiber Optic Cable Installation and Handling Instructions 11
Publication 2090-IN010C-EN-P – April 2005
Hard Clad Silica Glass Fiber Optic Cable Attenuation Limits
Hard Clad Silica Glass (HCS) Fiber cable attenuation calculations for cables <= 100m
HCS Cable Attenuation = Cable Loss + Connector Loss + Finishing Tolerance
HCS Cable Attenuation = ((15 - 4*log(Lkm))* Lkm) + 1.5dB + 0.5dB
Catalog Number
Length meters,
(inches)
Maximum
Attenuation
(dB)
Maximum
Attenuation
With Bulkhead
Conn.
2090-SCVG50-0
50, (1968)
3.01
NOT ALLOWED
2090-SCVG100-0
100, (3936)
3.90
NOT ALLOWED
2090-SCVG150-0
150, (5904)
3.90
NOT ALLOWED
2090-SCVG200-0
200, (7872)
3.90
NOT ALLOWED