10 Fiber Optic Cable Installation and Handling Instructions
Publication 2090-IN010C-EN-P – April 2005
6. Verify that optometer is set to measure appropriate wavelength and
attenuation in dB.
7. Use the dB value on the optometer to verify that the cable under test
is within specification listed in the table for that specific catalog
number.
8. Reverse the cable and test again starting at step 2.
Recommended Equipment List
650 nm LED Light Source - Tempo 253B
Optometer - Tempo CP-3137
Mating adapters for SMA connectors - Tempo 905-120-5000
• 1m HCS Reference Cable with recorded attenuation - XSOPTZCS
T01SSFSF0001MZ
• 1m POF Reference Cable - Tempo PO1XSFS0001M1