Monitor variables, 0x00 to, 0x00 to 0x0f – Rockwell Automation 2092-DAx Ultra1500 Host Commands for Serial Communication Reference Manual User Manual
Page 63: Refer to monitor variables on, See monitor variables
Publication 2092-RM001A-EN-P — March 2005
Error Codes, Warnings, and Monitor Variables
A-3
Monitor Variables
This table defines the variables that can be selected for the following
parameters:
[Pr – 5.12] Analog Output CH1 Selection on page 2-35,
[Pr – 5.13] Analog Output CH2 Selection on page 2-35,
[Pr – 5.14] Analog Output CH1 Scale on page 2-35,
[Pr – 5.15] Analog Output CH2 Scale on page 2-35
[Pr – 6.07] Fault Detail Data Selection 1 on page 2-37,
[Pr – 6.08] Fault Detail Data Selection 2 on page 2-37,
[Pr – 6.09] Fault Detail Data Selection 3 on page 2-37, and
[Pr – 6.10] Fault Detail Data Selection 4 on page 2-37.
Variable
Numbers
Name
Ultraware Name
Unit
0x00
Speed Feedback
Velocity Feedback
rpm or mm/sec
0x01
Speed Command
Velocity Command
rpm or mm/sec
0x02
Speed Error
Velocity Error
rpm or mm/sec
0x03
Current Command
Current Command
0.1% of motor rated continuous torque
0x04
Position Feedback
Follower Position
counts
0x05 Position
Command
Master
Position
counts
0x06
Position Error
Position Error
counts
0x07
Position Pulse Command Frequency
Position Command Count
Frequency
0.1 kilocounts/sec
0x08 Electrical
Angle
Commutation
Angle
0.1
o
(degrees)
0x09
Mechanical Angle
Mechanical Angle
0.1
o
(degrees)
0x0A
Regenerative Accumulation Loading Rate
Shunt Power Limit Ratio
%
0x0B
DC Link Rate
Bus Voltage
V
0x0C
Multi-rotation Data of Absolute Encoder
Absolute Rotations
revolutions
0x0D
Speed Command Offset
Velocity Command Offset
mV
0x0E
Current Command Offset
Current Command Offset
mV
0x0F
Input and Output Status
Size: 3 bytes
Bits 1 to 7 = Input Statuses
Bit 8 = Estop
(0 = Normal Operation)
Bits 9 to 11 = Output Statuses
Bit 12 = Fault
(0 = Fault, 1 = No fault)
Input and Output Status
0x10
U phase Current
U Phase Current
0.001 A
0x11
V Phase Current
V Phase Current
0.001 A
0x12
W Phase Current
W Phase Current
0.001 A
0x13
Motor Overload Percentage
Motor Temperature
%
0x14
Analog Velocity Command Voltage
Analog Command - Velocity
0.01 V
0x15
Analog Current Command Voltage
Analog Command - Current
0.01 V
Digital Outputs 3 - 1:
3 and 1 active
Servo Alarm:
No errors
E-Stop:
Not active
Digital Inputs 7 - 1:
6, 5, 3, and 1 active
7
1
3
1
2
3
2
5
4
6