Group 3 parameters, Pr - 3.00] follower, Group 3 parameters -28 – Rockwell Automation 2092-DAx Ultra1500 Host Commands for Serial Communication Reference Manual User Manual
Page 40: Pr – 3.00] follower -28

Publication 2092-RM001A-EN-P — March 2005
2-28
Command Reference
Group 3 Parameters
[Pr – 3.00] Follower
Data Size:
4 digits
Digit 0:
Command Type
Range:
Value Description
0x0
Step/Direction - CW + CCW, positive logic
0x1
Step/Direction - CW + CCW, negative
logic
0x2
Step Up/Step Down - Pulse Line + Sign,
positive logic
0x3
Step Up/Step Down - Pulse Line + Sign,
negative logic
0x4
Auxiliary Encoder - A Phase + B Phase,
positive logic
0x5
Auxiliary Encoder - A Phase + B Phase,
double input multiplication, positive logic
0x6
Auxiliary Encoder - A Phase + B Phase,
quadruple input multiplication, positive logic
For command types 0x4, 0x5, and 0x6:
Motor Counts = Master Lines * MULT * .... (4 * [Pr3.01]) / [Pr3.02]
where MULT is 1, 2, or 4 for command types 0x4, 0x5, and 0x6
respectively.
Default:
0x0
Operating Mode:
Follower
Digit 1:
Controller Output Type
Range:
Value Description
0x0
Line driver output to host controller.
0x1
Open collector output to host controller.
Default:
0x0
Operating Mode:
Follower
Digit 2:
Encoder Output Forward Direction
Range:
Value Description
0x0
During forward rotation, Encoder Output
Phase A have a lead of 90
° over Phase B.
0x1
During forward rotation, Encoder Output
Phase B have a lead of 90
° over Phase A.
Default:
0x0
Operating Mode:
All
Digit 3:
“Clear Pos Error” Input Mode