beautypg.com

Pr - 9.58] oscilloscope configuration, Pr – 9.58] oscilloscope configuration -46 – Rockwell Automation 2092-DAx Ultra1500 Host Commands for Serial Communication Reference Manual User Manual

Page 58

background image

Publication 2092-RM001A-EN-P — March 2005

2-46

Command Reference

[Pr – 9.58] Oscilloscope Configuration

[Pr – 9.59] Oscilloscope Scaling

Ultraware Name:

Scope Config

Data Size:

21 digits

Value

Description

0 to 1

Channel A Signal
See Monitor Variables on page A-3 for a list
of variables.

2 to 3

Channel B Signal
See Monitor Variables on page A-3 for a list
of variables.

4

Channel A Signal

0 = Auto (default)
1 = Manual

5

Channel B Scale Type

0 = Auto (default)
1 = Manual

6 to 7

Sample Period

8 to 9

Samples per Division

10 to 12

Trigger Signal
See Monitor Variables on page A-3 for a list
of variables.

13 Trigger

Mode

14 Pretrigger,

%/1

15 to 22

Trigger Threshold

Default:

0x00000000000000000000000000000000

Operating Mode:

All

Data Size:

32 digits

Value

Description

0 to 7

Channel A Scale

8 to 14

Channel A Offset

15 to 23

Channel B Scale

24 to 31

Channel B Offset

Default:

0x00000000000000000000000000000000

Operating Mode:

All