Pr - 6.07] fault detail data selection 1, Pr - 6.08] fault detail data selection 2, Pr - 6.09] fault detail data selection 3 – Rockwell Automation 2092-DAx Ultra1500 Host Commands for Serial Communication Reference Manual User Manual
Page 49: Pr - 6.10] fault detail data selection 4, Pr - 6.11] 2nd velocity regulator p gain, Pr - 6.12] 2nd velocity regulator i gain
Publication 2092-RM001A-EN-P — March 2005
Command Reference
2-37
[Pr – 6.07] Fault Detail Data Selection 1
[Pr – 6.08] Fault Detail Data Selection 2
[Pr – 6.09] Fault Detail Data Selection 3
[Pr – 6.10] Fault Detail Data Selection 4
[Pr – 6.11] 2nd Velocity Regulator P Gain
[Pr – 6.12] 2nd Velocity Regulator I Gain
Ultraware Name:
Fault Detail Setup: Channel A
Range:
Refer to Monitor Variables on page A-3.
Default:
0x00
Ultraware Name:
Fault Detail Setup: Channel B
Range:
Refer to Monitor Variables on page A-3.
Default:
0x03
Ultraware Name:
Fault Detail Setup: Channel C
Range:
Refer to Monitor Variables on page A-3.
Default:
0x0B
Ultraware Name:
Fault Detail Setup: Channel D
Range:
Refer to Monitor Variables on page A-3.
Default:
0x10
Ultraware Name:
Alternate Gain Values: VReg P Gain
Range:
0 to 1000
Default:
60
Operating Mode:
Follower, Analog Velocity, Preset
Ultraware Name:
Alternate Gain Values: VReg I Gain
Range:
0 to 60000
Default:
26
Operating Mode:
Follower, Analog Velocity, Preset