Read fault contents (ehy), Jog (jog), Read fault contents (ehy) -9 jog (jog) -9 – Rockwell Automation 2092-DAx Ultra1500 Host Commands for Serial Communication Reference Manual User Manual
Page 21: Read fault contents (ehy) jog (jog)
Publication 2092-RM001A-EN-P — March 2005
Command Reference
2-9
Read Fault Contents (EHY)
Jog (JOG)
Command:
EHY
Description:
Read faults
See “Read Fault Detailed Data (DIE)” on page 2-12 for alternative
fault data.
Format:
STX ID # EHY F1 : BSS ETX
Data:
Argument
Description
F1
Fault Number. Range is 0x01 to 0x08
where latest fault status is stored in 0x01, and
oldest fault is stored in 0x08.
Response Format: STX ID $ EHYE FCode FChars : BSS ETX
Data:
Data
Description
FCode
Fault Code. See Appendix A for a list of fault
codes.
FChars
Fault Name Abbreviated. See Appendix A.
Usage Note:
Use this command to find out more about one of the 8 faults.
To receive all fault statuses, use EHY * command below.
Command:
EHY *
Description:
Read all fault codes
Format:
STX ID # EHY * : BSS ETX
Data:
Argument
Description
*
Asterik (*) means all faults
Response Format: STX ID $ EHY Fcode1&Fcode2&...Fcode8 : BSS ETX
Data:
Data
Description
Fcode1 to Fcode8 Fault Code. See Appendix A for a list of fault
codes.
Command:
JOG
Description:
Jog forward or reverse
Format:
STX ID # JOG P1 : BSS ETX
Data:
Argument
Description
P1
0 = prepare for jog operation
+ = jog forward
- (dash) = jog reverse
Response:
ACK
Usage Note:
To keep jogging, JOG command must be sent more than once within
500 msec.
To end jog mode, send SVROF