Oc_getscanner watchdogcount, Oc_getscannerwatchdogcount -29 – Rockwell Automation 1747-PCIS API Software - Open Controller User Manual
Page 89

Publication 1747-UM002A-US-P - June 2000
Library of Routines 6-29
OC_GetScanner
WatchdogCount
OC_GetScannerWatchdogCount reads the contents of the watchdog
register of the scanner.
Syntax:
int
OC_GetScannerWatchdogCount(HANDLE handle, BYTE
*count);
Parameters:
Description:
The watchdog register is incremented by the scanner after every timed
I/O scan.
This register is incremented in both Scan and Idle modes, and is
incremented even if both output and input scans are disabled. The
control application can monitor this register to ensure that the scanner
is functioning normally. It is also useful for synchronizing with the I/O
scan.
Return Value:
Considerations:
Supported in the DOS API library and the Windows NT API library
Example:
HANDLE
Handle;
BYTE
wdog_count;
int
retcode;
retcode = OC_GetScannerWatchdogCount( Handle, &wdog_count );
Parameter:
Description:
handle
Must be a valid handle returned from OC_OpenScanner
count
Returns the watchdog register contents
Name:
Value:
Description:
SUCCESS
0
watchdog was read successfully
ERR_OCACCESS
2
handle
does not have access to scanner