OC_ResetScanner
OC_ResetScanner generates a hard or soft reset to the scanner.
Syntax:
int
OC_ResetScanner(HANDLE handle, int mode);
Parameters:
Description:
After the reset is generated, the scanner begins to execute its POST.
Return Value:
Considerations:
Supported in the DOS API library and the Windows NT API library
Example:
HANDLE
Handle;
int
retcode;
retcode = OC_ResetScanner( Handle, OCWAIT );
ATTENTION
!
This call stops scanning and resets outputs.
Parameter:
Description:
handle
Must be a valid handle returned from OC_OpenScanner
mode
If
mode
is:
OCNOWAIT
OC_ResetScanner returns after releasing the
reset signal to the scanner.
OCWAIT
OC_ResetScanner returns after POST is completed.
OCSOFTRESET
OC_ResetScanner reinitializes while avoiding the
7-second POST delay. In this mode, the scanner performs
a warm-boot and bypasses the POST. The dual-port RAM
can be epartitioned quickly.
The scanner stops scanning, resets all outputs, and
returns to the power-on condition. After the reset is
complete, you must call OC_InitScanner to initialize the
shared memory interface.
Name:
Value:
Description:
SUCCESS
0
scanner was reset successfully
ERR_OCACCESS
2
handle
does not have access to the scanner
ERR_OCPOST
7