PowerFlex 40 Standard Configured Drive Standard Features and Options
DeviceNet I/O (4 In/ 2 Out) w/Spring Return HOA, Power Disconnect
Aux. Contact, and 4 I/O Quick Disconnects (Position 16+, Code R5)
This option provides a factory installed 800F door mounted operator device, a
100-DNY42R mounted internal to the cabinet, a power disconnect auxiliary
contact, four I/O quick disconnects, and a 24V DC male receptacle.
The Hand/Off/Auto selector switch will start the drive while held in the Hand
mode and stop it in the Off mode. The default speed reference comes from
parameter P038, option 4 (Preset Freq). The selector switch has a spring return
disallowing the operator to remain in Hand. When in Auto the default speed
reference is derived parameter A051, option 4 (Preset Freq).
The 100-DNY42R is powered by DeviceNet and provides control based on
customer control parameters. The inputs and outputs are powered by customer
supplied 24V DC.
This options is prewired with an auto contact from the Hand/Off/Auto selector
switch between the I/O V+ and IN0 terminals. The main power disconnect
auxiliary contact is wired between the I/O V+ and IN1 terminals indicating if
the disconnect is on or off. The four I/O quick disconnects allow the customer to
quickly connect to the remaining two inputs and outputs that are available for
customer use.
Component Specifications
This option must be used with the drive mounted DeviceNet option D (Position
12) and is not compatible with options R3, R4, S1, S4, S7, S8, S20, S21 or S22.
The drive mounted DeviceNet and the 100-DNYR42 will appear as separate
nodes on the communication system.
Bulletin 800F Devices
IEC style, Internationally rated
Meet IP65/IP66 and NEMA/UL Type 4/4X/13
UL Listed, CSA Certified
10 amp contacts
Screw terminals, 0.3…3.5 mm
2
(22…12 AWG) maximum
Hand/Off/Auto
Selector Switch
3 position, Hand (spring return), Off, Auto (maintained)
3 N.O. & 3 N.C. contacts
Legend Plate
30 x 50 mm, Black with white lettering
Wiring
0.8 mm
2
(18 AWG), Blue
100-DNY42R
cULus Listed, CSA, CE
DeviceLogix™, Rotary address switches
24V DC or 120V AC inputs
High-Capacity transistor or Relay outputs
ODVA Compliance v2.0 Tested
Power Disconnect Auxiliary Contact
1 N.O. & 1 N.C. Side mounted contacts
Receptacle Shell
Black anodized machined aluminum
Connector Insert
Nylon
Contacts
Machined brass with gold over nickel plating
Schematic