15

7.1.3. Battery Current

This is the measurement of the battery current.

Negative battery current

Battery is powering the load.

Positive battery current

Battery is being charger by battery charger.

7.1.4. Supply Voltage

This is the measurement of power supply voltage.

7.1.5. System Temperature

This is the measurement of the enclosure temperature.

7.1.6. Capacity

This is the measurement of the battery’s capacity level. This reading is present
after the first test is completed.

7.1.7. IO Channel 1 – Analog V

This is the measurement of the voltage present across contact number 1.

7.1.8. IO Channel 1 – Digital In

This is the logic setting for IO Channel 1 (see port options menu).

TRUE

The logic level voltage for the port has been met. An alarm
message has been sent.

FALSE

The logic level voltage for the port has not been met. No alarm
message has been sent.

7.1.9. IO Channel 1 – Digital Out

This indicates that the IO Channel 1 relay has been set to indicate a battery
relate fault (see port options menu).

OFF

The relay is set for normal operation.

ON

The relay is set to indicate a battery fault as diagnosed by the
BTRM.