Roxul Industrial Insulation Process User Manual
Page 58
Insulation of c
olumns
1. Support construction - 2. Mounting support -
3. Reinforcement ring - 4. ProRox
®
insulation -
5. Cladding
In a wide variety of applications, these values can
only be used as reference values. In each
individual case, determine whether different strap
measurements and intervals should be used. If
the insulation is assembled in multiple layers,
the joints of the individual insulation layers must
be staggered. The following illustrations show a
number of typical methods of insulating columns.
External insulation
diameter
Internal insulation layer strap
measurement
External or single layer insulation
strap measurement
Distance between
the straps
8" to 72" (200 to 1800 mm)
1/2" x 0.02" (13 x 0.5 mm)
5/8" x 0.02" (16 x 0.5 mm)
10" (250 mm)
> 72" (1800 mm)
5/8" x 0.02" (16 x 0.5 mm)
3/4" x 0.02" (19 x 0.5 mm)
10" (250 mm)
2"
(50 mm
)
Insulation of conical column head
1. Supporting construction - 2. Mounting support
Insulation of a reinforcement ring
55