Robustel M1000 User Guide User Manual
Page 76
Robustel GoRugged M1000 User Guide
RT_UG_M1000 _v.2.0.0
20.12.2013
75 / 83
Confidential
0 - disable phone control DO output
1 - enable phone control DO output
onAction: alarm on action
1 - OFF
2 - ON
3 - Pulse
4 - Null
offAction : alarm off action
1 - OFF
2 - ON
3 - Pulse
4 - Null
flag1:
0 - DO open when power on
1 - DO close when power on
*keepOn: how many times the DO keeps
close (0 - 255)
1029 Set Pulse Parameters
cmd,low,high,output,delay
low: 1 - 30000
high: 1 - 30000
output: 0 - 30000
delay: 0 - 30000
1030
Set DO SMS Control
Parameters
cmd,onContent,offContent,group
*onContent: max 70 bytes
*offContent: max 70 bytes
group: 1 - 10 (phone group)
Get Commands
2000 Get Base Parameters
cmd
return:
1 - comm
2 - comm type
3 - device name
4 - ME Type
5 - IMEI
6 - auto CSD
7 - auto delete SMS
8 - sms control passwd
9 - SIM card pin setup
2001
Get SMS Direct
Parameters
cmd
return:
1 - sms in
2 - sms out
3 - auto add timestamp
4 - max SMS day sent
2002
Get Data Packing
Parameters
cmd
return:
1 - data packing interval timeout
2 - packet length