Serial Interface

Number of Ports: 1 x DB9 Female

Serial Standards: RS232 and RS485

ESD Protection: ±15KV

Baudrate: 8N1, 1200bps to 115200bps

RS-232: TxD, RxD, RTS, CTS, GND

RS-485: Data+ (A), Data- (B), GND


Digital Input

Type: Dry Contact, DI or event counter

Dry Contact: On: open, Off: short to GND

Isolation: 3K VDC or 2K Vrms

Counter Frequency: 900 Hz

Digital Filtering Time Interval: Software selectable

Digital Output

Type: Sink, DO or pulse output

Pulse Output Frequency: 1 kHz

Isolation: 3K VDC or 2K Vrms


System

LED Indicators: PWR, RUN, NET and 3 level RSSI

Real Time Clock: Built-in RTC with button battery

Watchdog and Timer: Built-in watchdog and timer


Power Supply and Consumption

Power Supply Interface: 2-pin 5mm pluggable terminal block

Input Voltage: 9 to 36 VDC

Power Consumption: Idle: 50-60 mA @ 12 V

Data Link: 100 to 200 mA (peak) @ 12 V


Physical Characteristics

Housing & Weight: Metal, 300g

Dimension(L x W x H): 102 x 71 x 29 mm

Installation: 35mm Din-Rail or wall mounting or desktop