beautypg.com

9 coil, Coil – Robustel M1000 User Guide User Manual

Page 33

background image

Robustel GoRugged M1000 User Guide


RT_UG_M1000 _v.2.0.0

20.12.2013

32 / 83

Confidential

Phone

Number

Address

The start address to save phone number, total 16 registers.

0

SMS

Content

Address

The start address to save SMS content, total 35 registers.

20

SMS

Notification

Function

Code

(0x02)

Read only parameters.
The function code for the PLC polling the modem to check whether
there is new SMS.

/

Have

New

SMS

(0x01)

Read only parameters.
During polling, when there is new SMS, modem will reply 0x01.

/

No New SMS (0x00)

Read only parameters.
During polling, when there is no new SMS, modem will reply 0x00.

/

PLC Get SMS From
Modem

Function

Code (0x04):

Read only parameters.
The function code for the PLC to read new SMS and get its content.

/

Read Phone Number
Address

The start address to save received SMS phone number, total 10
registers.

0

SMS Received Date
Address

The start address to save received SMS date, total 6 registers.

0

SMS

received

Content Address

The start address to save received SMS content, total 70 registers.

0

3.2.9 Coil

This tab describes Coil settings.