2 sms control steps, 3 sms commands list, Sms control steps – Robustel M1000 User Guide User Manual
Page 71: Sms commands list
Robustel GoRugged M1000 User Guide
RT_UG_M1000 _v.2.0.0
20.12.2013
70 / 83
Confidential
When there is a password, SMS command has following structure: Password:cmd1;cmd2;cmd3;…;cmdn
Cmd1, cmd2, cmd3 to Cmdn, which are command identification number 0000 – 9999
A, b, c to n, which are command parameters
The semicolon character (‘;’) is used to separate more than one commands packed in a single SMS.
5.3.2 SMS Control Steps
1. Use command Password:cmd1;cmd2;cmd3;…;cmdn or cmd1;cmd2;cmd3;…;cmdn to set new parameters.
2. After setting new parameters for M1000, remember to use 0004 command to save parameters and reset the
modem, then the new parameters will take effect.
3. In one SMS, if there is more than two cmd, remember to use punctuation “;” to divide each cmd.
Note: E.g., 1234:1001,M1000;0004
In this command, password is 1234, 1001 is the cmd to set device’s name, “M1000” is M1000’s name that we want to
set, then save parameters and reset the modem to take effect with command 0004.
5.3.3 SMS Commands List
Cmd Description
Syntax
Comments
Control Commands
0000 Set Factory Defaults
password:cmd or cmd
if no password, please use command
"cmd", or use command "password:cmd" if
there is a password.
Following commands are the same.
0001 Reset Device
cmd
0002 Save Parameters
cmd
0003 Get Device Status
cmd
0004
Save Parameters and
Reset Device
cmd
0005 Clear SMS Count
cmd
0006 Clear Event Count
cmd
0007 Start Event Counter
cmd
Set Commands
1000 Set Comm Parameters
cmd,baud rate,parity,data bits,stop
bits,flag
baud rate: 1200 - 115200
parity: n,o,e,m,s
data bits: 7,8
stop bits: 1,2
*flag:
0 - RS232
1 - RS485
1001 Set Device Name
cmd,name
name(max 20 bytes)
1002 Set SIM Card Pin
cmd,flag1,pin,flag2,newPin
flag1: