Robustel GoRugged M1000 User Guide


RT_UG_M1000 _v.2.0.0

20.12.2013

28 / 83

Confidential

SMS Direct

Note: This function is only available under “Config Mode”.

Item

Description

Default

Enable SMS-IN

Tick the SMS-IN checkbox to allow forwarding of incoming short messages from specified
Caller ID to the modem’s serial port as data.
The Caller ID (phone number) should be specified in “Phone Book” tab by inputting the
phone number and tick “SMS In” checkbox.

Disable

Enable
SMS-OUT

Tick the SMS-OUT checkbox to allow data received from the attached serial device to be
transmitted as short messages to Target Phone Number.
The Target Phone Number (phone number) should be specified in “Phone Book” tab by
inputting the phone number and tick “SMS Out” checkbox.

Disable

Text ASCII

7 bits text format (160 bytes per packet)

Disable

From Mobile

Enable when receiving text (ASCII) SMS from mobile phone.
Disable when receiving text (ASCII) SMS from mobile phone.

Disable

To Mobile

Enable when sending text (ASCII) SMS from mobile phone.
Disable when sending text (ASCII) SMS from mobile phone.

Disable

Unicode (UCS2) 16 bits Unicode (UCS2) format (70 bytes per packet)

Disable

Binary (8 bits)

8 bits binary (140 bytes per packet)

Disable

Auto

Add

Timestamp

Auto adds timestamp at the beginning of the SMS.
Timestamp format is dd.mm.yy hh:mm:ss

Disable

Max. SMS/Day

Set daily limitation for sending SMS in SMS Direct function, when reaching the maximum
limitation, M1000 will stop sending SMS any more at that day.
0 is no limitation.
Customer could also clear the counter by sending SMS to M1000 with SMS Control
privilege, the SMS is “clear sms counter

0

Receive

After enable SMS-IN function, Receive windows will be available, the incoming short
messages from specified Caller ID to the modem’s serial port will be displayed in this
item.

Disable

Send

After enable SMS-Out function, Send windows will be available, user could input any text
message in this item which will be transmitted as short messages to Target Phone
Number
.

Disable

Note:
1. The phone numbers for SMS Direct function can be set in Phone Book tab.
2. The Target Phone Number must be specified if SMS-OUT is activated.
3. The Target Phone Number and Caller ID must be written in international format, starting with “+” followed by

the country code.

4. If you leave Caller ID blank, the modem will allow all incoming short messages as serial data to be forwarded to

its serial port. This includes system broadcasts and advertisements.

5. The timeout between characters is 0.5 second. Messages that require a longer time period will be split into 2 or

more messages.

SMS Data Format

Text ASCII

7 bits text format (160 bytes per packet)

Unicode

16 bits Unicode (UCS2) format (70 bytes per