Robustel GoRugged M1000 User Guide
RT_UG_M1000 _v.2.0.0
20.12.2013
69 / 83
Confidential
Chapter 5.
Appendix
5.1 Factory Settings
Factory setting of the modem COM port under
Config Mode
is:
Data bits = 8
Parity = none
Stop bits = 1
Baud = 115200 bps
Flow control = none
Factory setting of the modem COM port under
Normal Mode
is: Autobauding
The autobauding mode allows the modem to automatically detect the transmission speed used by the DTE.
Only the following speeds will be detected: 300, 600, 1200, 2400, 4800, 9600, 14400, 19200, 28800, 38400, 57600,
115200bps. Auto-baud detection cannot be guaranteed for speeds below or above these speeds.
5.2 Restore to Factory Default
The modem could be restored to factory default by Modem Configurator, SMS and hardware operation.
Following steps indicate how to restore to factory default by hardware operation:
1. Set the modem under Normal Mode, power on the modem;
2. Within 3 seconds, change the modem from Normal Mode to Config Mode;
3. Within 3 seconds, change the modem from Config Mode to Normal Mode again;
4. Within 3 seconds, change the modem from Normal Mode to Config Mode again;
5. Restore successfully.
Note: PIN setting, Phone Book settings and COM settings will not be restored to factory default.
5.3 SMS Commands for Remote Control
5.3.1 SMS Commands Structure
M1000 supports remote configuration and remote modem status reading via SMS. An SMS command has following
structure: Password:cmd1,a,b,c;cmd2,d,e,f;cmd3,g,h,i;...;cmdn,j,k,n
Password: SMS control password is configured at Basic->SMS Control->Password, which is an optional
parameter.
When there is no password, SMS command has following structure: cmd1;cmd2;cmd3;…;cmdn