Robustel M1000 User Guide User Manual
Page 72
Robustel GoRugged M1000 User Guide
RT_UG_M1000 _v.2.0.0
20.12.2013
71 / 83
Confidential
0 - disable pin lock
1 - enable pin lock
pin(4 - 8 bytes)
flag2:
0 - disable change pin
1 - enable change pin
*newPin(4 - 8 bytes and can be null)
1003
Set SMS Control
Passwd
cmd,passwd
*passwd(max 20 bytes and can be null)
1004 Enable Auto CSD
cmd,flag
flag:
0 - disable
1 - enable
1005
Enable Auto Delete
SMS
cmd,flag
flag:
0 - disable
1 - enable
1006 Set SMS in
cmd,flag1,format,flag2
flag1:
0 - disable SMS in
1 - enable SMS in
format:
0 - text ASCII
1 - Unicode(UCS2)
2 - Binary(8 bits)
flag2:(only avaible in format "text ASCII")
0 - from mobile
1 - not from mobile
1007 Set SMS out
cmd,flag1,format,flag2
flag1:
0 - disable SMS out
1 - enable SMS out
format:
0 - text ASCII
1 - Unicode(UCS2)
2 - Binary(8 bits)
flag2:(only avaible in format "text ASCII")
0 - to mobile
1 - not to mobile
1008
Enable Auto Add
Timestamp
cmd,flag
flag:
0 - disable
1 - enable
1009 Set Max SMS Day Sent cmd,value
value: 0 - 10000
1010
Set Data Packing
Interval Timeout
cmd,timeout
timeout: (2 - 100)* 100ms
1011 Set Packet Length
cmd,length
length: 0 - 1024