71 / 83
Confidential
0 - disable pin lock 
1 - enable pin lock 
pin(4 - 8 bytes) 
flag2: 
0 - disable change pin 
1 - enable change pin 
*newPin(4 - 8 bytes and can be null) 
1003
Set SMS Control 
Passwd 
cmd,passwd
*passwd(max 20 bytes and can be null)
1004 Enable Auto CSD
cmd,flag
flag: 
0 - disable 
1 - enable 
1005
Enable Auto Delete 
SMS 
cmd,flag
flag: 
0 - disable 
1 - enable 
1006 Set SMS in
cmd,flag1,format,flag2
flag1: 
0 - disable SMS in 
1 - enable SMS in 
format: 
0 - text ASCII 
1 - Unicode(UCS2) 
2 - Binary(8 bits) 
flag2:(only avaible in format "text ASCII") 
0 - from mobile 
1 - not from mobile 
1007 Set SMS out
cmd,flag1,format,flag2
flag1: 
0 - disable SMS out 
1 - enable SMS out 
format: 
0 - text ASCII 
1 - Unicode(UCS2) 
2 - Binary(8 bits) 
flag2:(only avaible in format "text ASCII") 
0 - to mobile 
1 - not to mobile 
1008
Enable Auto Add 
Timestamp 
cmd,flag
flag: 
0 - disable 
1 - enable 
1009 Set Max SMS Day Sent cmd,value
value: 0 - 10000
1010
Set Data Packing 
Interval Timeout 
cmd,timeout
timeout: (2 - 100)* 100ms
1011 Set Packet Length
cmd,length
length: 0 - 1024