Page 74
Robustel GoRugged M1000 User Guide
RT_UG_M1000 _v.2.0.0
20.12.2013
73 / 83
Confidential
0 - don't ignore AT^SMSO
1 - ignoreAT^SMSO
value: 0 - 60s (power on delay turn on
module)
1020
Set Singal Update
Frequency
cmd,value
value: 5 - 1200s
1021 Set Init String
cmd,index,content
index: 0 - 3(0 - M1000 will auto generate a
index when the init string array isn't full)
content: max 40 bytes
1022 Set Phone Number
cmd,index,number,flag
index: 0 - 10(0 - M1000 will auto generate a
index when the phone book isn't full)
number(max 20 bytes)
flag: xxxxx (binary format: 00000 - 11111)
flag.0:
0 - disable call reboot
1 - enable call reboot
flag.1:
0 - disable sms reboot
1 - enable sms reboot
flag.2:
0 - disable sms in
1 - enable sms in
flag.3:
0 - disable sms out
1 - enable sms out
flag.4:
0 - disable sms control
1 - enable sms control
1023 Set Phone Group
cmd,index,flag
index: 1 - 10(phone group index)
flag: xxxxxxxxxx (binary format:
0000000000 - 1111111111)
flag.0 ~ flag.9: (phone number index)
0 - exclude in this phone group
1 - include in this phone group
1024
Set Modbus
Parameters
cmd,flag1,id,address1,address2,flag2,
address3,address4,address5,address
6,address7
flag1:
0 - enable modbus
1 - disable modbus
*id - slave address
*address1 - coil address
*address2 - register address
*flag2:
0 - enable PLC send SMS
1 - disable PLC send SMS