beautypg.com

Trouble shooting – MacDon 9250 SP User Manual

Page 120

background image

Form # 46584

Issue 11/06 Web Rev_01

118

TROUBLE SHOOTING


SYMPTOM

PROBLEM

SOLUTION

REF.

Air conditioning not
cooling. (continued)

Loose or broken drive
belt.

Replace drive belt and/
or tighten to specs.

66

Compressor partially or
completely seized.

Remove compressor for
service or replacement.

*

Dirty filters.

Clean fresh air and re-
circulation filters.

110, 111

Broken or disconnected
electrical wire.

Check all terminals for
loose connections;
check wiring for hidden
breaks.

---

Broken or disconnected
ground wire.

Check ground wire to
see if loose, broken, or
disconnected.

---

Expansion valve stuck
in open or closed
position.

Replace expansion
valve.

*

Broken refrigerant line.

Examine all lines for
evidence of breakage
by external stress or
rubbing wear.

*

Leak in system.

Leak-test system; repair
leaks as necessary.

*

Compressor shaft seal
leaking.

Replace compressor
shaft seal.

*

Clogged screen in
receiver-drier; plugged
hose or coil.

Repair as necessary.
Replace receiver-drier;
evacuate and charge.

*

Air conditioning not
producing sufficient
cooling. (Sufficient
cooling defined as when
air temperature in cab,
measured at louvered
vent, can be maintained
at 25

°F (14°C) below

ambient air
temperature.)

Compressor clutch
slipping.


Clogged air filter.



Heater circuit is open.

Too little air circulation
over condenser coil; fins
clogged with dirt or
insects.

Remove clutch
assembly for service or
replacement.

Remove air filter and
clean or replace as
necessary.

Close heater valves
(1 in cab, 1 at engine).
Clean condenser.

*



110



21

79

Evaporator fins clogged.

Clean evaporator fins
(under seat)

111


Too little refrigerant in
system.

Recharge system until
gauge readings stabilize
to specifications.

112

* See your Windrower dealer

This manual is related to the following products: