beautypg.com

Technical specifications – Opticon RFS 6000 User Manual

Page 10

background image

U

SER

S

& S

ET UP MANUAL

RFS 6000

10

5.4

Environmental specifications

Temperature

0 - +55 oC in operation

-40 - +70 oC in storage

Emission

According to EN50081, part 1

Immunity

According to EN50082, part 1

R&TTE

conform I-ETS 300-220

5.5

Physical specifications

Dimensions

125 x 140 x 180 mm

(l x w x h)

(incl. antenna)

Weight

260 g

Standard cable

DB25 male / DB9 female

5.1

Electrical specifications

Voltage requirement 5V ± 5 %

Current consumption

Typical use 100 mA

Max. 180 mA

5.2

Transceiver specifications

Frequency

433.92 MHz license free band

Transceiving system

RF-DC
aerial antenna system

Operation range

up to 50 meters distance from
antenna, depending on
environment characteristics

ERP max. 10

mW

(effective radiated power)

Transmission speed

up to 38400 bits/s
(practical transmission speed

depends on application)

5.3

Functionality

Memory

32 KByte ROM

128 KByte FlashROM

for program storage

32 KByte RAM

Microprocessor

16-bit

Firmware

updates may be downloaded
via RS232 cable

Interfaces supported

RS232
RS485

TECHNICAL
SPECIFICATIONS

3

5