Technical Specification
9. TeCHNICAL speCIFICATIoN
Frame
Consumer / Professional, up to 24 bit,
Sampling frequency f
s
= 32 – 96 kHz,
Also supports: Interleaved 96 kHz mode
on all inputs (single channel double
sampling frequency modes)
Measurements
Signal
Level-FS, level-RMS, signal frequency,
THD+N, event logger, frequency sweep,
PPM, scope, overload detection,
Full-Scale detection
Carrier
Sampling frequency (accuracy ±2.5 ppm),
carrier level
Frame
Channel status according to AES 3
(ed. 2003) and IEC 60958-3 (ed. 2003),
bit statistics
Event logger
Recording resolution selectable 1”, 10”, 1’, 10’, 1h
Recording duration selectable 8’, 83’, 8h, 83h, 20days
Display Δt
1”, 10”, 1’, 10’, 1h, 10h, 24h, all
Recording intervals max. 500
Single errors in one
recording interval
10 - 36 000
I
nput connectors
AES 3 (110 Ohm) XLR, S/PDIF (RCA),
TOS-Link, ADAT,
AES 3id (75 Ohm) using Chinch-BNC
adapter, phantom power resistant
Monitor
Built-in speaker, headphone connector
Display
Backlit graphic LCD
Power supply
- 3x AA size dry batteries (alkaline),
typical lifetime 8 hours
- External DC power, 7.5 VDC, 500 mA,
stabilized, use NTi Audio recommended
parts only