beautypg.com

Rx 1510-c/-i/-ci, Maintaining the machine – Multiquip RX 1510-C/-I/-CI User Manual

Page 83

background image

RX 1510-C/-I/-CI

– 83 –

Only original RAMMAX spare hydraulic line lines offer the security of using the
correct line type (pressure stage) in the right situation.

• Check the tightness of all connections and screw connections after accomplishing

any type of work (on a pressure-free system!!).

• Hydraulic lines may not be swapped.
• Hydraulic lines must be visually checked regularly.
• Immediate replacement of the hydraulic hoses is necessary in the following

cases:
– Damages to the outer layer up to the inset. (e.g. chafing, cuts).
– Embrittlement of the outer layer (cracked formation on the line material).
– Deformation in pressureless or pressurised condition which does not

correspond with the original shape of the hydraulic line.

– Deformation on bending, e.g. crushing points, kinks, separation of plies,

formation of blisters.

– Leaking

parts.

– Incorrectly executed installation.
– Migration of the hydraulic line from the fitting.
– Corrosion of the fitting, which reduces function and stability.
– Damage to or deformation of the fitting, which reduces the function and stability

or the connection line/line.

Maintaining the machine