beautypg.com

Multiquip RX 1510-C/-I/-CI User Manual

Page 66

background image

RX 1510-C/-I/-CI

– 66 –

.

F 40 I0

2

5.3.2 Stand-by

mode

The machine reverts to the standby mode, if it is not started within 30 seconds.
The machine can nevertheless be started in this state with one of the control
modes or with the ignition key.

Stand-by : No display active. Only the decimal point

flashes.

NOTE

A low current always flows in the "Standby" mode.The ignition lock serves as
battery disconnection switch.
► In the case of longer work breaks switch ignition off, in order to avoid battery

discharge..

5.3.3

Starting the machine at the ignition lock

Before starting, put the control levers and/or control keys for the vibration function
in the neutral position.

► Turn the ignition key to position "2". The following code is displayed: „F 4010”.

The LEDS for generator and oil pressure drop extinguish. The starter is active,
as long as the ignition key is at the "Ignition position 2".

Starting procedure

Start-up