Multiquip RX 1510-C/-I/-CI User Manual
Page 57

RX 1510-C/-I/-CI
– 57 –
Driving functions
Display
Executed functions
F I 0010
Driving
Right
forward
F I 0011
Driving
Right forward
High speed
F I 0020
Driving
Right
backward
F I 0021
Driving
Right backward
High speed
F I 0100
Driving
Left
forward
F I 0101
Driving
Left forward
High speed
F I 0110
Driving
Left forward
Right forward
F I 0111
Driving
Left forward
Right forward
High speed
F I 0120
Driving
Left forward
Right backward
F I 0121
Driving
Left forward
Right backward
High speed
F I 0200
Driving
Left
backward
F I 0201
Driving
Left backward
High speed
F I 0210
Driving
Left backward
Right forward
F I 0211
Driving
Left backward
Right forward
High speed
F I 0220
Driving
Left backward
Right backward
F I 0221
Driving
Left backward
Right backward
High speed
4.4.6
Cockpit display with infrared control
Start / Stop function
Characteristic
Control mode
Code
number:
Meaning:
F
I
4010
Toggle switch„Start” is activated. ► Starting procedure is
initiated.
F
I
4020
The motor has started. ► Release toggle switch „Start”.
F
-
4050
This error message appears, if the toggle switch is released
during the starting procedure, the engine has not yet started
and it is set to start again immediately after releasing the toggle
switch. This function prevents the starter engaging, while the
engine is still in motion.
F
I
4100
Toggle switch„Stop” is activated. ► Stop procedure is initiated.
► The machine controller waits, until the generator signal, the
speed signal and the oil pressure signal are not sent anymore.
F
I
4200
Stop sequence is continued.
F
I
4300
The operating hour meter is secured. K15 is then switched off.
F
I
4400
The operating hour meter is saved".
Display and operating elements: