Routine maintenance overview checklist, Routine maintenance overview checklist 88 – MTS Series 505 SilentFlo Hydraulic Power Unit Model 505-180 User Manual
Page 88

Model 505.60 - 505.180 SilentFlo™ HPU
88
Routine Maintenance Overview Checklist
Maintenance
Routine Maintenance Overview Checklist
Recommended service to be performed at each running time interval noted
Calendar Time using 8 hour
Running Time rate per day
Daily
Weekly
Monthly
Annually
Running Time-Hours
8
40
160
500
1000 1,500 2,000
5,000 10,000
Check electronic enclosure
ventilation
X
*
Check dirty filter indicators
X
Check for leaks
X
Check oil level
X
Check pressure
X
Check fluid color and odor
X
Check interlock devices
X
Check cables and connectors
X
Check console air filter
MTS
†
Check all accumulators for
proper precharge pressure
and oil
MTS
MTS
MTS
MTS
Check condition of all
electrical cables and cable
connections
MTS
MTS
MTS
MTS
Check HPU hydraulic fluid
color and odor
MTS
MTS
MTS
MTS
Check HPU operating
pressure and temperature
MTS
MTS
MTS
MTS
Clean control cabinet air filter,
replace if required
MTS
MTS
MTS
MTS
Inspect heat exchanger for
leaks or “flow (when off)”
MTS
MTS
MTS
MTS
Inspect pump hoses for leaks
MTS
MTS
MTS
MTS
Lubricate-grease motor
bearings (non 505)
MTS
MTS
MTS
MTS
Verify dirty filter indicators
status
MTS
MTS
MTS
MTS
Verify HPU hydraulic fluid
level
MTS
MTS
MTS
MTS
Verify warning and interlock
devices
MTS
MTS
MTS
MTS